Chapter 10 Device HA
NWA3000-N Series User’s Guide
134
10.3.1 Edit Monitored Interface
This screen lets you enable or disable monitoring of an interface and set the
interface’s management IP address and subnet mask. To access this screen, click
Configuration > Device HA > Active-Passive Mode > Edit.
Figure 59 Device HA > Active-Passive Mode > Edit Monitored Interface
Password Enter the password used for verification during synchronization. Every
NWA3000-N series AP in the virtual router must use the same
password.
If you leave this field blank in the master NWA3000-N series AP, no
backup NWA3000-N series APs can synchronize from it.
If you leave this field blank in a backup NWA3000-N series AP, it cannot
synchronize from the master NWA3000-N series AP.
Auto
Synchronize
Select this to get the updated configuration automatically from the
specified NWA3000-N series AP according to the specified Interval.
The first synchronization begins after the specified Interval; the
NWA3000-N series AP does not synchronize immediately.
Interval When you select Auto Synchronize, set how often the NWA3000-N
series AP synchronizes with the master.
Apply This appears when the NWA3000-N series AP is currently using active-
passive mode device HA. Click Apply to save your changes back to the
NWA3000-N series AP.
Reset Click Reset to return the screen to its last-saved settings.